Message Long Text :

Cause . . . . . : A problem with a disk device was detected during vary-on of an Auxiliary Storage Pool (ASP) device. The problem was with disk unit number &2, subunit &3. The source of the error is &4 with 1 being the only or the production copy of the ASP and 2 being the geographic mirroring mirror copy. The reason code is &1.
The reason codes are:
1310 - The disk unit is missing from the configuration.
1316 - The mirror level of protection is lower.
1317 - The disk device should be reformated to improve performance.
1318 - The disk device in the device parity set has failed and the device parity set is exposed to future failures.
1320 - The disk device does not have pages available for error recovery procedures.
1323 - The disk device compression status does not match what the system expected.
1324 - A path to a multiple path unit is missing.
Recovery . . . : Contact your next level of support.