Ansicht
Dokumentation

CPDE024 - Cannot send configuration data to IP over IPX support. ( OS/400 )

CPDE024 - Cannot send configuration data to IP over IPX support. ( OS/400 )

TXBHW - Original Tax Base Amount in Local Currency   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.
SAP E-Book


Message : CPDE024
Cannot send configuration data to IP over IPX support.

Message Long Text :

Cause . . . . . : The IP over IPX support was not activated because errors occurred while trying to send the address mapping configuration.
Recovery . . . : See the previously listed messages in the QLUS job log. Correct the errors and then try activating the IP over IPX support again. To try activating IP over IPX support again, do one of the following:
-- Issue the Change Network Attributes (CHGNETA) CL command with the allow AnyNet support (ALWANYNET parameter) set to *NO, and then issue the command again with ALWANYNET set to *YES.
-- Issue the End IPX ENDIPX) CL command and then issue the Start IPX (STRIPX) CL command.
If the problem continues, report the problem using the Analyze Problem (ANZPRB) CL command.

Message File : QCPFMSG
Library Message File : QSYS2924


General Material Data   General Data in Customer Master  
This documentation is copyright by IBM.

Length: 3242 Date: 20240424 Time: 194023     sap01-206 ( 3 ms )