Message : CPDE029
Automatic configuration of network objects for IPX circuit &1 failed.

Message Long Text :

Cause . . . . . : IPX circuit &1 uses line description &3. The automatic configuration of the network controller and *IPX type network device failed. The reason code is &9.
The reason codes and their meanings follow:
-- 0001 - Line description &3 not in the proper state.
-- 0002 - Network controller &11 is not in the proper state.
-- 0003 - Device &10 is not in the proper state.
-- 0004 - Unable to vary on line description &3.
-- 0005 - Unable to vary on network controller &11.
-- 0006 - Unable to vary on the network *IPX type device &10.
-- 0007 - Unable to create the network controller description &11.
-- 0008 - Unable to create the network *IPX type device description &10.
-- 0009 - QSYS user profile does not have authority to line description &3.
Recovery . . . : Based on the reason code, do one of the following, and then try the request again:
-- 01, 02, 03, 04, 05, and 06 Use the Work with Configuration Status (WRKCFGSTS) CL command to view the current state of line description &3, the network controller &11 or the network device &10. Ensure that the object is not in DAMAGED, FAILED, RCYPND or RCYCNL state. If the object is in DAMAGED state use the Delete Line Description (DLTLIND) CL command, or the Delete Controller Description (DLTCTLD) CL command, or the Delete Device Description (DLTDEVD) CL command to delete the object. If you deleted line description &3 then create it again using the CRTLINxxx CL command. where xxx is equal to the line type of the line description. If the object is in any other state, vary off the object using the Vary Configuration (VRYCFG) CL command.
-- 07 and 08 Use the Work with Configuration Status (WRKCFGSTS) CL command to view the network controller &11 or the network device &10. If the object already exists, use the Delete Device Description (DLTDEVD) or the Delete Controller Description (DLTCTLD) CL commands to delete the object.
-- 09 Use the Grant Object Authority (GRTOBJAUT) CL command to grant the QSYS user profile authority to line description &3.

If the circuit still fails to start, report the problem using the Analyze Problem (ANZPRB) CL command.