Ansicht
Dokumentation

CPF1239 - Subsystem &1 cannot start prestart job &2. ( OS/400 )

CPF1239 - Subsystem &1 cannot start prestart job &2. ( OS/400 )

PERFORM Short Reference   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF1239
Subsystem &1 cannot start prestart job &2.

Message Long Text :

Cause . . . . . : User &5 is not authorized to class &6 in library &7 specified in the prestart job entry for program &3 in library &4.
Recovery . . . : Have the security officer grant *USE authority (GRTOBJAUT command) for the class. Then wait until message CPC0905 is shown on the system operator (QSYSOPR) message queue, indicating the entry is no longer active. To start new jobs, enter the Start Prestart Jobs (STRPJ) command.

Message File : QCPFMSG
Library Message File : QSYS2924