CPF1272 - Internal object is damaged. ( OS/400 )
CPI1466 during Backup General Data in Customer MasterThis documentation is copyright by IBM.
Message : CPF1272
Internal object is damaged.
Message Long Text :
Cause . . . . . : An internal object used for communications device &1 is damaged. If the device is an APPC device, mode &2 is being used. No new jobs can be started for this device until the device has been varied off and then on again (VRYCFG command), but jobs already started will continue to run normally.
Recovery . . . : If new jobs are to be started for this device, then vary the communications device off and then on again (VRYCFG command). If the device fails to vary on, power down the system (PWRDWNSYS command) and IPL it again.
Message File : QCPFMSG
Library Message File : QSYS2924