Ansicht
Dokumentation

CPF1398 - Subsystem &1 varied off work station &3. ( OS/400 )

CPF1398 - Subsystem &1 varied off work station &3. ( OS/400 )

PERFORM Short Reference   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF1398
Subsystem &1 varied off work station &3.

Message Long Text :

Cause . . . . . : The subsystem received &7 while using file &4 in library &5 record format &6.
-- At least three other non-recoverable errors (a combination of CPF1189 or CPF1194) have been encountered for this work station since the subsystem last received valid input from it.
-- It is possible that the subsystem cannot recover the device and a loop is in progress.
-- If the problem with the device is not corrected the subsystem will de-allocate the work station, issue a CPF1399, and will not attempt to reallocate the device.
Recovery . . . : Find out what is causing the problem with the device. The subsystem's job log may contain more information about the nature of the problem (DSPJOBLOG command).
-- Correct the problem, then vary the device on (VRYCFG command).
-- If this message is handled in a break message handling program, the program should not automatically vary the device off and on.
-- The subsystem will allocate the work station when it is available.

Message File : QCPFMSG
Library Message File : QSYS2924


Fill RESBD Structure from EBP Component Structure   BAL_S_LOG - Application Log: Log header data  
This documentation is copyright by IBM.

Length: 3234 Date: 20240425 Time: 031345     sap01-206 ( 2 ms )