Message : CPF2556
Sequence number &1 not defined in system reply list.

Message Long Text :

Cause . . . . . : A reply list entry with the specified sequence number was not found in the system reply list.
Recovery . . . : Change the sequence number and try the command again. To find the correct sequence number use the WRKRPYLE command, or add the entry to the system reply list (ADDRPYLE command).

Message File : QCPFMSG
Library Message File : QSYS2924