Ansicht
Dokumentation
CPF2667 - Identifier &1 entry cannot be changed while controller attached. ( OS/400 )
PERFORM Short Reference TXBHW - Original Tax Base Amount in Local CurrencyThis documentation is copyright by IBM.
Message : CPF2667
Identifier &1 entry cannot be changed while controller attached.
Message Long Text :
Cause . . . . . : The logical channel entry with identifier &1 cannot be changed because there is a controller description currently attached to this logical channel.
Recovery . . . : Use the Display Line Description (DSPLIND) command to view what is currently defined for this line description. Do one of the following and then try the request again:
-- If the logical channel type is to be changed for the logical channel entry with identifier &1, delete the attached controller description (DLTCTLD command) and then change the logical channel type.
-- If the logical channel type is not intended to be changed, then correct the specified logical channel type to match what is currently defined in the line description.
Technical description . . . . . . . . : Before changing a logical channel entry that is attached to a controller description, the controller description must be deleted.
Message File : QCPFMSG
Library Message File : QSYS2924
rdisp/max_wprun_time - Maximum work process run time BAL_S_LOG - Application Log: Log header data
This documentation is copyright by IBM.