Ansicht
Dokumentation

CPF2673 - Line &1 not compatible with controller. ( OS/400 )

CPF2673 - Line &1 not compatible with controller. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF2673
Line &1 not compatible with controller.

Message Long Text :

Cause . . . . . : Create line command failed. The reason code is &2. Reason codes and their meanings follow:
1101 -- The controller name specified cannot be attached to the line description.
1102 -- The controller name specified is attached to another line description.
1103 -- The controller name is specified more than once.
1104 -- The controller name specified is not compatible with the line description because:
-- The controller cannot be defined as switched.
-- The controller data link role cannot be the same as the data link role on the line.
-- When a controller has a network device of type *IPXD attached to it, the attached line for the controller must be a Token-Ring, Ethernet, or Frame Relay line.
-- The controller type cannot attach to this line type. For X.25 lines, the controller logical channel identifier must specify a permanent virtual circuit (PVC) logical channel identifier defined for the line.
1105 -- The controller in the switched controllers list (SWTCTLLST parameter) is either the wrong type (for example, 5294 instead of BSC or asynchronous), or the controller is not defined as switched or switched network backup. For X.25 lines, the controllers must be defined as switched call-in asynchronous X.25.
1106 -- If controller name (CTL) or SWTCTLLST is specified, duplicate controller addresses exist.
1113 -- The X.25 default receive packet size (DFTPKTSIZE parameter) on the controller description is greater than the maximum receive packet size (MAXPKTSIZE parameter) on the line description.
1114 -- The maximum frame size (MAXFRAME parameter) value on the controller description is greater than MAXFRAME value on the line description.
1116 -- The X.25 default receive window size (DFTWDWSIZE parameter) on the controller description is not compatible with MODULUS parameter value on the line description.
1161 -- The X.25 default transmit packet size (DFTPKTSIZE parameter) on the controller description is greater than the maximum transmit packet size (MAXPKTSIZE parameter) on the line description.
1162 -- The X.25 default transmit window size (DFTWDWSIZE parameter) on the controller description is not compatible with MODULUS parameter value on the line description.
Recovery . . . : Correct any errors, then try the request again.

Message File : QCPFMSG