Ansicht
Dokumentation

CPF4795 - 3270 API formatted header or data not valid. ( OS/400 )

CPF4795 - 3270 API formatted header or data not valid. ( OS/400 )

Vendor Master (General Section)   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF4795
3270 API formatted header or data not valid.

Message Long Text :

Cause . . . . . : Data written to the host system from an application program using the Systems Network Architecture 3270 application program interface (SNA 3270 API) with a formatted interface was not valid.
The data was not translated for transmission to the host system.
Recovery . . . : Correct the data in the SNA 3270 API header in your program, and attempt the output operation again. Compile your program again if necessary.
Technical description . . . . . . . . : The following are possible reasons as to why translation was not successful:
-- The attention identification (AID) field in the SNA 3270 API common header was not valid for a 3270 data stream.
-- The cursor position field (bytes 5,6) in the SNA 3270 API common header did not have values binary 1 through binary 3564, depending on the 3278 display image size.
-- The 1 byte pseudo-attributes in the display image was changed to a value other than '01'X.
-- The number of field entries was larger than the number previously returned.
-- The user sent data that was not appropriate for the data flow.
The format type field (*FIELD), extended field (*EXTFIELD) or no field (*NOFIELD) for the SNA 3270 API formatted interface is specified on the emulation device (EMLDEV) parameter on the Add ICF Device Entry (ADDICFDEVE) command, the Change ICF Device Entry (CHGICFDEVE) command or the Override ICF Device Entry (OVRICFDEVE) command. The SNA 3270 API common header and display or printer image provide information that needs to be translated into a 3270 data stream. The translation was not successful.
The format type field (*FIELD), extended field (*EXTFIELD) or no field (*NOFIELD) for the SNA 3270 API formatted interface is specified on the emulation device (EMLDEV) parameter and the output length buffer value is not equal to or larger than the 32XX screen plus the header size.

Message File : QCPFMSG
Library Message File : QSYS2924


TXBHW - Original Tax Base Amount in Local Currency   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.

Length: 3244 Date: 20240425 Time: 183704     sap01-206 ( 2 ms )