Ansicht
Dokumentation
CPF5207 - Block that is not valid in file sequence number &20. ( OS/400 )
PERFORM Short Reference BAL Application Log DocumentationThis documentation is copyright by IBM.
Message : CPF5207
Block that is not valid in file sequence number &20.
Message Long Text :
Cause . . . . . : A block length that is not valid was read from the tape in file sequence number &20 volume &6 on device &4, and a condition code &9 while processing file &2 in &3. The contents of the block cannot be processed as valid records. The blocks previously read may not be valid.
Recovery . . . : Create the file on tape again, and try the request again. Use the DMPTAP command to determine the contents of the tape.
Technical description . . . . . . . . : The condition code identifies the specific error:
1 -- There is not enough room left in the block for a record or record segment.
2 -- A record or segment description in the block contains length value that cannot be processed or is not valid.
3 -- The spanned record segments are out of order, or segment type that is not valid was found.
4 -- An invalid block or record descriptor was found. The format specified for tape processing may not be valid.
Message File : QCPFMSG
Library Message File : QSYS2924
Vendor Master (General Section) General Data in Customer Master
This documentation is copyright by IBM.
Length: 3244 Date: 20240425 Time: 144044 sap01-206 ( 2 ms )