Message : CPF5D2A
Error occurred, and processing cannot continue.

Message Long Text :

Cause . . . . . : An error has occurred, and processing cannot continue. The error code is &1.
01 = The wrong number of parameters have been passed to the program update interface.
02-04 = Information about the program cannot be materialized.
05-06 = Program update interface internal values are unexpected.
07 = Unexpected error while processing procedure order list.
Recovery . . . : Specific recoveries for the error code include:
01 = Contact your service representative for the correct program update interface parameters.
02-04 = The bound program or service program being updated is too large or may be damaged. Create the bound program or service program again using the Create Program (CRTPGM) or Create Service Program (CRTSRVPGM) command.
05-07 = Contact your service representative.

Message File : QCPFMSG
Library Message File : QSYS2924


CL_GUI_FRONTEND_SERVICES - Frontend Services   BAL Application Log Documentation  
This documentation is copyright by IBM.