Ansicht
Dokumentation

CPF671B - Block size mismatch from &1 to &2. ( OS/400 )

CPF671B - Block size mismatch from &1 to &2. ( OS/400 )

BAL Application Log Documentation   SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF671B
Block size mismatch from &1 to &2.

Message Long Text :

Cause . . . . . : Volume &3 on device &1 cannot be duplicated to device &2. The block size of the tape volume &3 is &5, and device &2 and/or its corresponding I/O Processor does not support this block size. The maximum block size supported by device &2 is &6.
Recovery . . . : Do one of the following:
-- Duplicate the tape to a device and/or I/O Processor that supports a block size of &5.
-- Recreate tape volume &3 without specifying USEOPTBLK(*YES) for save/restore files or without specifying a block length greater than &5. Then attempt the command again.
Technical description . . . . . . . . : If device &1 is a media library device, then volume &3 has a cartridge identifier of &7. If device &2 is a media library device, then volume &4 has a cartridge identifier of &8.

Message File : QCPFMSG
Library Message File : QSYS2924


General Material Data   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.

Length: 3222 Date: 20240329 Time: 125503     sap01-206 ( 3 ms )