Ansicht
Dokumentation

CPF6778 - Cartridge &6 in error on device &2. ( OS/400 )

CPF6778 - Cartridge &6 in error on device &2. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   PERFORM Short Reference  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF6778
Cartridge &6 in error on device &2.

Message Long Text :

Cause . . . . . : Cartridge &6 in library device &2 is in error. The operation involving the cartridge was &3 which is defined by one of the following operation types:
1 -- The cartridge error occurred while attempting to move the cartridge.
2 -- The cartridge error occurred while a category selection was specified to the library device manager.
3 -- The cartridge error occurred while the automatic cartridge loader fill or clear operation was being performed.
4 -- The condition was detected in an operation not included in the other operations above.
The type of error on cartridge &6 was &4 which is defined by one of the following exception codes:
1 -- The cartridge ID in the input station has either an unreadable external label, did not have an external label, or was not an ID that follows naming conventions for the library device manager. The cartridge may not correctly have a seventh character to indicate to the library device manage the cartridge type. The cartridge was left in the input station.
2 -- During an operation other than an inventory, a cartridge was detected in a storage slot or other position that was not expected. If the cartridge had a readable external cartridge ID and the cartridge is not in the library device inventory, or the cartridge does not have a readable external cartridge ID then the cartridge has been removed to an output station.
3 -- The cartridge has been marked unavailable.
4 -- A cartridge that had previously been marked unavailable has been made available.
Recovery . . . : The error may be an information only from the library device manager, but the type of error on cartridge &6 was &4 which is may be recoverable by the following:
1 -- Determine why the system could not determine the cartridge ID of the cartridge in error and retry the operation.
2 -- Determine what cartridge has been removed to an output station and reinsert the cartridge after verifying the correct label.
3 -- Determine why the cartridge is unavailable, make it available, and retry the operation.
4 -- The cartridge has been made available. The message was signalled for information only.
Technical description . . . . . . . . : The following information was passed from the library manager, &1.