Ansicht
Dokumentation

CPF6797 - Command did not complete on device &25. ( OS/400 )

CPF6797 - Command did not complete on device &25. ( OS/400 )

PERFORM Short Reference   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF6797
Command did not complete on device &25.

Message Long Text :

Cause . . . . . : A device failure occurred because the response from the device was not received in the specified time.
Recovery . . . : Vary off device &25 and then on again through the Work with Configuration Status (WRKCFGSTS) command with CFGTYPE(*DEV) specified. Then try the request again. If the job will not start again, a new failure message will be sent. If the problem continues, press F14 to run problem analysis.
Technical description . . . . . . . . :

-- Error Log Id .................. : &22
-- Reference Code ................ : &33
-- Device Type ................... : &34

The failure in the device has occurred during the processing of a command. The failure stopped the command from running and the processing of the command did not complete.

Message File : QCPFMSG
Library Message File : QSYS2924


CL_GUI_FRONTEND_SERVICES - Frontend Services   PERFORM Short Reference  
This documentation is copyright by IBM.

Length: 3235 Date: 20240420 Time: 050738     sap01-206 ( 4 ms )