Ansicht
Dokumentation

CPF7020 - Journal receivers &3 and &5 detached. ( OS/400 )

CPF7020 - Journal receivers &3 and &5 detached. ( OS/400 )

SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   General Material Data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF7020
Journal receivers &3 and &5 detached.

Message Long Text :

Cause . . . . . : Journal receiver &3 in library &4 and &5 in library &6 were detached from journal &1 in library &2. The journal receivers were detached from journal &1 for one of the following reasons:
- a user issued a Change Journal (CHGJRN) command to attach new journal receivers
- a user issued a Delete Journal (DLTJRN) command
- the system performed the change journal function for a journal that is defined as MNGRCV(*SYSTEM)
If only one receiver was detached, *N in library *N will be the second receiver name.
Technical description . . . . . . . . : If journal &1 in library &2 is a remote journal, and if the user issued the DLTJRN command, journal receiver &3 in &4 will be considered a partial journal receiver and will have no detach time associated with it.

Message File : QCPFMSG
Library Message File : QSYS2924


rdisp/max_wprun_time - Maximum work process run time   General Data in Customer Master  
This documentation is copyright by IBM.

Length: 3227 Date: 20240329 Time: 054044     sap01-206 ( 3 ms )