Ansicht
Dokumentation
CPF704F - TOJOBO or TOJOBC parameter not valid for receiver range. ( OS/400 )
BAL Application Log Documentation SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3upThis documentation is copyright by IBM.
Message : CPF704F
TOJOBO or TOJOBC parameter not valid for receiver range.
Message Long Text :
Cause . . . . . : Journal receiver &1 in library &2 does not include the job name field in its journal entries. Therefore, the TOJOBO or the TOJOBC parameter cannot be specified to end the Apply Journaled Changes (APYJRNCHG) or Remove Journaled Changes (RMVJRNCHG) command.
Specifying a value for the TOJOBO or the TOJOBC parameter is only valid if every journal receiver specified in the receiver range (RCVRNG parameter) has the job name field in its journal entries. The job name field is omitted from the journal entries for a journal receiver if RCVSIZOPT(*MINFIXLEN) is in effect when the journal receiver is attached to the journal.
Recovery . . . : For the Apply Journaled Changes (APYJRNCHG) command, do not use the TOJOBO or the TOJOBC parameter to specify when the apply journaled changes operation is to end. Instead, use the TOENTLRG or the TOENT or the TOTIME parameter to specify when the apply journaled changes operation is to end.
For the Remove Journaled Changes (RMVJRNCHG) command, do not use the TOJOBO parameter to specify when the remove journaled changes operation is to end. Instead, use the TOENTLRG or the TOENT parameter to specify when the remove journaled changes operation is to end.