Ansicht
Dokumentation

CPF7070 - Recovery of journal &1 in &2 failed. ( OS/400 )

CPF7070 - Recovery of journal &1 in &2 failed. ( OS/400 )

BAL Application Log Documentation   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF7070
Recovery of journal &1 in &2 failed.

Message Long Text :

Cause . . . . . : The system failed while the receiver directory for journal &1 in library &2 was being modified. Recovery of the receiver directory was not successful.
Recovery . . . : Do the following:
1) End journaling for all objects using one or more of the following:
-- End Journal Access Paths (ENDJRNAP)
-- End Journaling Physical File Changes (ENDJRNPF)
-- End Journal (ENDJRN)
-- End Journal Object (ENDJRNOBJ)
-- End Journal Library (ENDJRNLIB)
2) Save all associated receivers that have not been saved yet, but may be needed for later data recovery.
3) Delete journal &1 in library &2.
4) Delete all associated journal receivers.
5) Either restore the journal from a previously saved version, or create a journal receiver (CRTJRNRCV command) and create the journal (CRTJRN command) again.
6) If other associated journal receivers are needed, restore them from previously saved versions.

Message File : QCPFMSG
Library Message File : QSYS2924


RFUMSV00 - Advance Return for Tax on Sales/Purchases   General Material Data  
This documentation is copyright by IBM.

Length: 3240 Date: 20240420 Time: 152543     sap01-206 ( 3 ms )