Ansicht
Dokumentation

CPF7091 - Entry not journaled to journal &1. Reason code &3. ( OS/400 )

CPF7091 - Entry not journaled to journal &1. Reason code &3. ( OS/400 )

rdisp/max_wprun_time - Maximum work process run time   CPI1466 during Backup  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF7091
Entry not journaled to journal &1. Reason code &3.

Message Long Text :

Cause . . . . . : The entry was not journaled into receiver &8 in library &9 for journal &1 in library &2 because of reason code &3. If the error has already been corrected due to message CPA7090, ignore this message. The object associated with this entry is &4 in library &6 of type *&7 member &5, or has file ID &10 and path &12. If *N or hex zero appears, information is not available or does not apply.
Reason code definitions:
1 -- Space for entry cannot be allocated on journal receiver.
2 -- Journal is damaged.
3 -- Attached receiver is damaged.
4 -- Journal sequence number is at the maximum value.
5 -- An internal journal failure occurred.
7 -- Attached receiver is off line.
8 -- Journal is off line.
9 -- A new journal receiver must be attached to the journal.
10 -- Journal state is *INACTIVE.
11 -- Journal is a remote journal.
12 -- Entry exceeds the maximum journal entry size.
13 -- Unable to allocate large or very large space.
14 -- Journal state is *STANDBY.
Recovery . . . :
If receiver &8 in library &9 is no longer attached to journal &1, recovery using CHGJRN to attach a new receiver may not be required.
Recovery for each reason code is:
1 -- If the owning user or group profile of the journal receiver has reached its storage limit, increase the maximum storage (MAXSTG parameter on CHGUSRPRF). If the journal receiver has reached its maximum size, change the journal (CHGJRN) to attach a new receiver.
2-4 -- CHGJRN to attach a new receiver and if necessary reset the sequence number. If problem persists, delete the journal and either create or restore the journal. To delete a journal, end journaling all objects (ENDJRNAP, ENDJRNPF, ENDJRN, ENDJRNOBJ, ENDJRNLIB), and remove any associated remote journals (RMVRMTJRN command or QjoRemoveRemoteJournal API). With a new journal, start journaling all objects (STRJRNPF, STRJRNAP, STRJRN, STRJRNOBJ, STRJRNLIB) and add any remote journals (ADDRMTJRN command or QjoAddRemoteJournal API).
5,7,8,13 -- Report problem (ANZPRB). Then recover as described for reason codes 2-4.
9 -- CHGJRN to attach a new receiver.
10,14 -- Activate the journal (JRNSTATE parameter on CHGJRN command or the QjoChangeJournalState API).
11 -- Do not send journal entries to a remote journal, this is not allowed.
12 -- Change the operation attempted so its journal entry will have a size less than &11 bytes.

Message File : QCPFMSG
Library Message File : QSYS2924