CPF70D5 - Remote journal environment ended for journal &1 in library &2. ( OS/400 )

CPF70D5 - Remote journal environment ended for journal &1 in library &2. ( OS/400 )

General Data in Customer Master   Addresses (Business Address Services)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF70D5
Remote journal environment ended for journal &1 in library &2.

Message Long Text :

Cause . . . . . : Remote journal environment was ended for journal &1 in library &2 in Auxilary Storage Pool (ASP) group &8.
The reason code is &6.
1 - Unknown exception
3 - Catastrophic error
4 - Communication line error or target system error
5 - Target system error
6 - Source system ended the environment
7 - Storage limit exceeded for system, user or group profile
8 - Journal is damaged
9 - Journal receiver is damaged
10 - Receiving environment ended unexpectedly
11 - Time out waiting for a response from the target system
12 - Asynchronous remote journaling could not keep up
13 - Incompatible systems
14 - Unable to allocate large or very large space
15 - Target system does not support journal sequence numbers larger than 2,147,483,648
16 - Target system does not support terabyte journal receivers
17 - Target system does not support journal entries larger than 15MB
18 - Target system does not support standby journal state
19 - Target system does not support journal sequence numbers larger than 9,999,999,999
20 - Source system detected a take down of the remote journal environment from the target system
21 - Source system could not detect the target system
22 - Target system does not support JRNOBJLMT(*MAX10M)
23 - Target system does not support MINENTDTA(*FLDBDY)
27 - Target system does not support VLDCHK(*ENABLED)
28 - Communication validity check failed
32 - RCVSIZOPT value of *MAXOPT1, *MAXOPT2, or *MAXOPT3 required for remote journal filtering
The remote journal environment that ended was &7.
1 - Sending environment
2 - Receiving environment
3 - Both the sending and receiving environments
Recovery . . . : See message CPI7012 or CPI7031 following this message for recovery procedures. For some reason codes, if the remote journal environment was set to automatically restart, the system will attempt to reactivate the remote journal every &14 seconds up to &13 attempts.
Technical description . . . . . . . . : If this is a remote journal, the source journal is &3 in library &4 on system &12 in Auxilary Storage Pool (ASP) group &9.
If this is a local journal, the transport mechanism is &10. The relational database name is &5. The data port node identifier is &11.

Message File : QCPFMSG
Library Message File : QSYS2924


rdisp/max_wprun_time - Maximum work process run time   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.

Length: 3308 Date: 20240425 Time: 120857     sap01-206 ( 2 ms )