CPF70E7 - MINENTDTA value not allowed with JRNRCV(*SAME). ( OS/400 )
TXBHW - Original Tax Base Amount in Local Currency SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3upThis documentation is copyright by IBM.
Message : CPF70E7
MINENTDTA value not allowed with JRNRCV(*SAME).
Message Long Text :
Cause . . . . . : The minimize entry specific data (MINENTDTA) parameter is allowed to change only when new journal receivers are being attached to the specified journal.
Recovery . . . : Either omit the MINENTDTA parameter or change the JRNRCV parameter to something other than *SAME. Then try the command again.
Message File : QCPFMSG
Library Message File : QSYS2924
BAL Application Log Documentation BAL Application Log Documentation
This documentation is copyright by IBM.