CPF70F5 - Receiver threshold value is not valid. ( OS/400 )

CPF70F5 - Receiver threshold value is not valid. ( OS/400 )

SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   Addresses (Business Address Services)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF70F5
Receiver threshold value is not valid.

Message Long Text :

Cause . . . . . : Because MNGRCV(*SYSTEM) has been specified for this journal, the to be attached receiver must have a threshold value other than *NONE and at least &2 kilobytes.
Recovery . . . :
If JRNRCV(*GEN) was specified when changing journal receivers (CHGJRN command), try the operation again specifying a THRESHOLD value other than *NONE that is &2 kilobytes or greater.
If a receiver name was specified when changing journal receivers or when creating a journal (CRTJRN command), delete the to be attached receiver and create a new journal receiver (CRTJRNRCV command) specifying a THRESHOLD value other than *NONE that is &2 kilobytes or greater. Then try the operation again using this new journal receiver.
If you do not want the system to manage the receivers for this journal and you want a THRESHOLD value of *NONE, try the operation again specifying MNGRCV(*USER).
Technical description . . . . . . . . : If you were attempting a CHGJRN operation and specified JRNRCV(*GEN) THRESHOLD(*SAME), you can determine the currently attached receivers threshold value by using the Work with Journal Attributes (WRKJRNA) command and selecting the display attributes option for the currently attached receiver.

Message File : QCPFMSG
Library Message File : QSYS2924