CPF70F6 - RCVSIZOPT value specified not allowed. ( OS/400 )
CPI1466 during Backup RFUMSV00 - Advance Return for Tax on Sales/PurchasesThis documentation is copyright by IBM.
Message : CPF70F6
RCVSIZOPT value specified not allowed.
Message Long Text :
Cause . . . . . : The receiver size options (RCVSIZOPT) parameter is removing the *MAXOPT1 or *MAXOPT2 option and SEQOPT(*RESET) was not specified.
Recovery . . . : Either add *MAXOPT1 or *MAXOPT2 to the RCVSIZOPT parameter or specify SEQOPT(*RESET). Then try the command again.
Technical description . . . . . . . . : This journal has *MAXOPT1 or *MAXOPT2 option currently in effect. The *MAXOPT1 and *MAXOPT2 options allow the journal receiver to have sequence numbers up to 9,999,999,999 and a maximum receiver size of approximately one terabyte (1,099,511,627,776 bytes). If *MAXOPT1 or *MAXOPT2 are not specified, the journal receiver can only support sequence numbers up to 2,147,483,136 and a receiver size of approximately 2 gigabytes.