CPF7A17 - Trace already is active. ( OS/400 )
ROGBILLS - Synchronize billing plans BAL Application Log DocumentationThis documentation is copyright by IBM.
Message : CPF7A17
Trace already is active.
Message Long Text :
Cause . . . . . : A TRCINT command was attempted for an active trace table with either
- SET(*SIZE) specified
- SET(*ON) with the SIZE parameter specified.
- SET(*ON) with TRCTYPE(*TTPERF) parameter specified.
Recovery . . . :
Do one of the following, then try the TRCINT command again.
1) If specifying SET(*ON), either omit the SIZE parameter or the TRCTYPE(*TTPERF) parameter.
2) Print the existing trace records by specifying SET(*OFF).
3) Write the existing trace records to tape or diskette by specifying SET(*SAVE).
4) Clear the existing trace records by specifying SET(*END).
Message File : QCPFMSG
Library Message File : QSYS2924
Fill RESBD Structure from EBP Component Structure Addresses (Business Address Services)