Ansicht
Dokumentation
CPF8910 - Controller &1 not valid for pass-through. ( OS/400 )
TXBHW - Original Tax Base Amount in Local Currency ABAP Short ReferenceThis documentation is copyright by IBM.
Message : CPF8910
Controller &1 not valid for pass-through.
Message Long Text :
Cause . . . . . : The specified controller name is not described as a virtual work station controller, or has no attached virtual devices.
Recovery . . . : Correct the name of the virtual controller and then try the request again.
Technical description . . . . . . . . : If no virtual controller exists, create a virtual work station controller (CRTCTLVWS command) with the specified name, &1, on the target system and add the proper virtual devices. If the virtual controller, &1, exists on the target system but has no attached virtual devices, create one or more virtual devices (CRTDEVDSP command) and specify &1 on the controller parameter. Then try the request again.
Message File : QCPFMSG
Library Message File : QSYS2924
Fill RESBD Structure from EBP Component Structure SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up
This documentation is copyright by IBM.
Length: 3225 Date: 20240423 Time: 193240 sap01-206 ( 3 ms )