Ansicht
Dokumentation

CPF899E - Error in input parameter list. ( OS/400 )

CPF899E - Error in input parameter list. ( OS/400 )

General Data in Customer Master   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF899E
Error in input parameter list.

Message Long Text :

Cause . . . . . : The program was ended for reason code &1. The reason codes are defined as follows:
01 -- A function was requested that is not allowed while running in the current program state.
02 -- The input parameters do not correspond to the values specified for the directory supplier system &2.
03 -- The input parameters cannot be validated. The associated record does not exist in the directory supplier table for system &2.
Recovery . . . : The collector system will attempt to shadow directory data from the supplier system again on the next shadow date and time. The next shadow date and time can be changed on the collector system by using the Change Directory Shadow System (CHGDIRSHD) command. Do one of the following based on the reason code:
01 -- Correct the parameter list passed to the program and try the request again.
02 -- To collect from supplier system &2 use the CHGDIRSHD command and change the next shadow date and time.
03 -- Supplier system &2 no longer exists in the supplier table. To collect from the system again use the Add Directory Shadow System (ADDDIRSHD) command.

Message File : QCPFMSG
Library Message File : QSYS2924


General Material Data   BAL Application Log Documentation  
This documentation is copyright by IBM.