Ansicht
Dokumentation
CPF9364 - Type field in controller description &24 is not valid for location &4 in network &5. ( OS/400 )
CPI1466 during Backup rdisp/max_wprun_time - Maximum work process run timeThis documentation is copyright by IBM.
Message : CPF9364
Type field in controller description &24 is not valid for location &4 in network &5.
Message Long Text :
Cause . . . . . : An attempt was made by location &4 in network &5 to start communications with this system on work station controller description &24, but TYPE field in controller description &24 is not valid for this controller.
Recovery . . . : Delete controller description &24 (DLTCTLD) and create a new work station controller description using the Create Controller Description (CRTCTLRWS) command with the correct TYPE (5394 or 5494), a local location of &14 (LCLLOCNAME parameter), a remote location of &4 (RMTLOCNAME parameter) and a remote network identifier of &5 (RMTNETID parameter), then vary on this work station controller description using the Vary Configuration (VRYCFG) command.
Message File : QCPFMSG
Library Message File : QSYS2924
SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up
This documentation is copyright by IBM.