CPF9B09 - Cannot add more controllers to line. ( OS/400 )

CPF9B09 - Cannot add more controllers to line. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.
SAP E-Book


Message : CPF9B09
Cannot add more controllers to line.

Message Long Text :

Cause . . . . . : The line already has the maximum number of controllers allowed.
Recovery . . . : Add the controller to a different line, or delete a controller from the line and try the request again.
Technical description . . . . . . . . : The maximum number of controllers on a line is determined by the line connection type (CNN) parameter and the maximum controllers (MAXCTL) parameter. A nonswitched point-to-point line (CNN = *NONSWTPP) can have only one controller.