CPFBB66 - Request failed for device cluster resource group &3. ( OS/400 )

CPFBB66 - Request failed for device cluster resource group &3. ( OS/400 )

ROGBILLS - Synchronize billing plans   ABAP Short Reference  
This documentation is copyright by IBM.
SAP E-Book


Message : CPFBB66
Request failed for device cluster resource group &3.

Message Long Text :

Cause . . . . . : An error occurred on node &4 for hardware specified in cluster resource group &3. The resource name &1 can be found in the configuration object. The logical resource name is &2. If the logical or hardware resource name is *NONE, the name could not be determined. The failure reason code is &5. The reason codes are:
36 and 41 -- An invalid configuration exists on the high-speed link.
37 -- A configured disk unit that is part of the same high-speed link I/O bridge or I/O processor is not configured in the same cluster resource group. Switching the cluster resource group would also switch the disk that is not part of the cluster resource group.
38 -- A configured disk unit is part of the same high-speed link I/O bridge or I/O processor which has other disk units configured in an auxiliary storage pool. Switching the cluster resource group which contains the auxiliary storage pool would also switch this disk unit.
39 -- Virtual OptiConnect is not configured.
40 -- High-speed link OptiConnect is not configured.
42 -- A high-speed link I/O bridge exists on a high-speed link segment that will be switched from one system to another because of its position on the high-speed link but it is either not configured into a cluster resource group or is configured into a different cluster resource group.
43 -- A high-speed link I/O bridge is not configured properly.
Recovery . . . : Recovery actions for each reason code are:
36 -- A cluster node cannot access the hardware. This node must be removed from the cluster resource group's recovery domain.
37 and 38 -- Change the configuration so that disks that would be switched together when a cluster resource group is switched are in auxiliary storage pools that are in the same cluster resource group.
39 and 40 -- Use dedicated service tools to configure the type of OptiConnect that is required.
41 -- On the high-speed link, either a private high-speed link I/O bridge or another system resides between the nodes in the recovery domain. If a private high-speed link I/O bridge exists on the link, remove it from the link or make the high-speed link I/O bridge switchable.
42 -- Review the high-speed link configurations that are allowed for switching high-speed link I/O bridges. Either remove the high-speed link I/O bridge from the high-speed link segment or configure the high-speed link I/O bridge as part of the same cluster resource group that will switch other high-speed link I/O bridges that are on this segment.
43 -- Use iSeries Navigator to enable switching for the high-speed link I/O bridge.
Technical description . . . . . . . . : Internal interface code is &6.