Message : CPFBB80
Request failed for device cluster resource group &3.

Message Long Text :

Cause . . . . . : An error occurred on node &4 for hardware specified in cluster resource group &3. The resource name &1 can be found in the configuration object. The logical resource name is &2. If the logical or hardware resource name is *NONE, the name could not be determined. The failure reason code is &5. The reason codes are:
16 -- The device is still varied on.
17 -- Configuration of disk units is in progress.
18 -- The operating system software of one or more logical partitions is at a release level prior to V5R1M0.
19 -- Hardware associated with an I/O processor cannot be switched to a node in different physical system.
20 -- Hardware associated with auxiliary storage pool is not assigned to an I/O pool, or it is assigned to an I/O pool but the node does not have access to the pool.
21 -- The primary node no longer owns the hardware.
22 -- An I/O processor which has the load source disk unit cannot be switched to another node.
23 -- The primary node no longer owns the hardware.
24, 25 and 26 -- The I/O processor is attached to a bus which cannot be shared with this cluster node.
Recovery . . . : Recovery actions for each reason code are:
16 -- The device must be varied off before it can be switched to another node.
17 -- An auxiliary storage pool cannot be switched to another node at the same time that disk unit configuration is occurring. Submit the request again when the disk unit configuration is complete.
18 -- The primary logical partition and all logical partitions that are recovery domain nodes in the cluster resource group must be at V5R1M0 or greater.
19 -- Either remove nodes on different physical system from the recovery domain or add nodes in the logical partitions of the same physical system to the recovery domain.
20 -- Use Hardware Management Console to add the hardware to an I/O pool if it is not currently assigned. Also verify that all recovery domain nodes have access to the I/O pool.
21 -- Either change the cluster resource group to the node that does own the hardware or move the hardware back to the primary node.
22 -- Remove the device entry from the cluster resource group or move the load source disk unit to another I/O processor.
23 -- Either change the cluster resource group to the node that does own the hardware or move the hardware back to the primary node.
24, 25 and 26 -- Change the configuration of the bus so that it can be shared by other cluster nodes or remove the devices from the cluster resource group which are on the bus so that bus is not part of the switched configuration.