Request failed for device cluster resource group &3.

Message Long Text :

Cause . . . . . : An error occurred on node &4 for hardware specified in cluster resource group &3. The resource name &1 can be found in the configuration object. The logical resource name is &2. If the logical or hardware resource name is *NONE, the name could not be determined. The failure reason code is &5. The reason codes are:
27 -- One or more connections to a disk unit are missing.
28 -- The hardware configuration has been changed and a high-speed link I/O bridge has been removed, or this node cannot access the high-speed link I/O bridge.
29 -- If all systems which share a high-speed link I/O bridge fail or are powered off or hardware in a tower fails, configuration information may be lost.
30 -- A high-speed link I/O bridge which has the load source disk unit cannot be switched to another node.
31 -- High-speed link I/O bridges on a high-speed link segment are in different power domains.
32 -- This type of high-speed link I/O bridge cannot be switched between cluster nodes.
33 -- Hardware which controls power to the device has failed.
34 -- One or more configured disk units in auxiliary storage pools are not operational.
35 -- One or more configured disk units are missing in auxiliary storage pools.
Recovery . . . : Recovery actions for each reason code are:
27 -- Identify the missing connections to the disk unit.
28 -- Remove the node which cannot access the hardware from the cluster resource group's recovery domain.
29 -- Ensure all systems and high-speed link I/O bridges on the high-speed link I/O bridge are powered on and operational
30 -- Remove the device entry from the cluster resource group or move the load source disk unit to another high-speed link I/O bridge.
31 -- Follow proper procedures to change the power domain cable of the high-speed link I/O bridges so that each high-speed link I/O bridge on this high-speed link segment is in the same power domain.
32 -- Remove the device entry for this hardware from the cluster resource group.
33 -- Use the product activity log to find entries for the failed hardware. Fix the failing hardware.
34 -- Use the product activity log to find entries for the failed hardware. Fix the failing hardware and submit the request again.
35 -- All added disk units must present in auxiliary storage pools. Fix the problem and submit the request again.
Technical description . . . . . . . . : Internal interface code is &6.

Message File : QCPFMSG
Library Message File : QSYS2924


BAL Application Log Documentation   CPI1466 during Backup  
This documentation is copyright by IBM.

Length: 3272 Date: 20240425 Time: 132545     sap01-206 ( 3 ms )