Ansicht
Dokumentation

CPFC418 - Problem detected with iSCSI boot on remote server. ( OS/400 )

CPFC418 - Problem detected with iSCSI boot on remote server. ( OS/400 )

SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   PERFORM Short Reference  
This documentation is copyright by IBM.
SAP E-Book


Message : CPFC418
Problem detected with iSCSI boot on remote server.

Message Long Text :

Cause . . . . . : The system was not able to boot the remote server from an iSCSI adapter because reason code &1. This remote server is associated with network server configuration (NWSCFG) &3. The associated network server description (NWSD) is &4.
Reason code:
01 -- An iSCSI adapter might not be installed or does not support iSCSI boot.
02 -- The boot device ID (BOOTDEVID) is set to *SINGLE. More than one iSCSI adapter is installed in the remote server.
03 -- No iSCSI adapter is detected in the remote server at the location specified by the boot device ID (BOOTDEVID).
04 -- Remote server hardware or firmware does not support iSCSI boot.
05 -- iSCSI boot failed: error code &2.
06 -- iSCSI Boot configuration failed.
Recovery . . . :
Reason code:
01 -- Install a supported iSCSI adapter in the remote server.
02-03 -- Use the Change NWS Configuration (CHGNWSCFG) command to change the BOOTDEVID to specify which iSCSI adapter will be used to boot from.
04 -- The hardware or the firmware of the remote server may need to be updated.
05 -- See the "Troubleshooting" topic in the "System i integration with BladeCenter and System x" category of the i5/OS information center.
06 -- Contact your technical support provider.

Message File : QCPFMSG
Library Message File : QSYS2924


BAL Application Log Documentation   SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up  
This documentation is copyright by IBM.

Length: 3258 Date: 20240420 Time: 041736     sap01-206 ( 3 ms )