CPFC781 - Failed to end the integrated Web application server. Reason &1. ( OS/400 )

CPFC781 - Failed to end the integrated Web application server. Reason &1. ( OS/400 )

RFUMSV00 - Advance Return for Tax on Sales/Purchases   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.
SAP E-Book


Message : CPFC781
Failed to end the integrated Web application server. Reason &1.

Message Long Text :

Cause . . . . . : An error occurred when stopping the integrated Web application server. The reason code is &1. Reason codes and their meanings follow:
1 - Profile not found in registry
2 - Unable to load profile data from i5OSstartup.properties. Error: &2.
3 - Unable to find webcontainer.port in config.properties. Error: &2.
4 - Unable to find adminAuthPattern Error: &2.
5 - Failed to get socket. Error: &2
6 - connect failed. Error: &2
7 - send failed. Error: &2
8 - error in ioctl. Error: &2
9 - recv failed. Error: &2.
10 - Unknown error: &2.
Recovery . . . : Depending on the error, do one of the following:
- verify an entry exists in the registry for the profile
- verify an i5OSstartup.properties file exists for the profile entry
- check for network problems

Message File : QCPFMSG
Library Message File : QSYS2924