Message : CPFCE04
A data stream error was detected.

Message Long Text :

Cause . . . . . : An invalid data stream was detected by the transform services program while processing primary input file &3. The reason code was &1. The meaning of the reason codes are:
1 -- A structured field had an invalid length or value.
2 -- An End Document structured field not found.
3 -- The referenced media map was not found. The correct form definition may not have been specified.
4 -- A required repeating group was not found in the form definition.
5 -- Incorrect image data encountered.
Refer to the Mixed Object Document Content Architecture Reference (SC31-6802) or for additional information on the AFP data stream.
Recovery . . . : Correct the data stream error and try the request again.
Technical description . . . . . . . . : The internal message identifier is &2. The error was encountered at offset &4.