Ansicht
Dokumentation

CPG0546 - Axis range not correct. ( OS/400 )

CPG0546 - Axis range not correct. ( OS/400 )

CPI1466 during Backup   Fill RESBD Structure from EBP Component Structure  
This documentation is copyright by IBM.
SAP E-Book


Message : CPG0546
Axis range not correct.

Message Long Text :

Cause . . . . . : An error occurred in function &1 called from application &2 at statement &3. No data is plotted. One of the axes has a lower limit, higher limit, or range (difference between limits) that is not valid. The absolute value of the limits (if not zero) and of the range must be greater than 1.0E -018 and less than 1.0E +018. You can specify the limits with the CHXRNG or CHYRNG commands or GDDM will calculate the limits for the data (autoranging). When using autoranging, you can cause the axis range to be extended to include zero, to include a specified intercept, or to include an integral number of major tick intervals. The range limits apply to the axis after any such extension has been applied.
Recovery . . . : Restrict the axis range and/or data values to be greater than 1.0E -018 and less than 1.0E +018. Then try the request again.

Message File : QCPFMSG
Library Message File : QSYS2924


Fill RESBD Structure from EBP Component Structure   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.

Length: 3205 Date: 20240416 Time: 175224     sap01-206 ( 3 ms )