Communications port &6 removed or failed.

Message Long Text :

Cause . . . . . : The system did not detect a communications port which was detected on previous IPLs. The port has type &1, model &2, and serial number &3. The direct select address was &4, the unit address was &5 and the resource name is &6. The part number is &10.
Recovery . . . : Do one of the following:
-- If the resource has been removed, use the WRKHDWRSC command to remove the item with resource name &6. WRKHDWPRD will automatically remove the item, if another resource is in the same slot.
-- If the resource is in an expansion unit that is powered off, follow correct procedures to power it on.
-- If the resource is installed and powered on, either the communications I/O adapter or the communications I/O processor may not be working correctly. Print this screen, or copy on paper the Serial number, the Message ID for this message, the system Machine type of &13, the system serial number of &14, the resource name &12, part number &10, part number &15, and the failing item code FI00100. Part number &10 should be replaced before part number &15. Use the ANZPRB command to report this problem, using the system machine type and system serial number that you printed or copied from this message.

Message File : QCPFMSG