Ansicht
Dokumentation

CPI1163 - No hot spare disk units remain on I/O adapter. ( OS/400 )

CPI1163 - No hot spare disk units remain on I/O adapter. ( OS/400 )

Fill RESBD Structure from EBP Component Structure   Addresses (Business Address Services)  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI1163
No hot spare disk units remain on I/O adapter.

Message Long Text :

Cause . . . . . : All hot spare disk units on I/O adapter have been consumed or have failed. No data has been lost. The following information identifies the I/O adapter (IOA):
IOA serial number: &27
IOA type: &3
IOA model: &4
Device resource name: &26
Recovery . . . : Do the following:
1. Type the Start System Service Tools (STRSST) command and press the Enter key.
2. Select the option to Work with disk units and press the Enter key.
3. Select the option to Display disk configuration and press the Enter key.
4. Select the option to Display device parity status and press the Enter key.
5. The Hot Spare Protection column identifies which parity set is no longer protected by a hot spare unit.
See the previously listed messages in this message queue to determine the failure on the device parity protected units or hot spare disk units. Perform the recommended recovery procedures.

Message File : QCPFMSG
Library Message File : QSYS2924


Fill RESBD Structure from EBP Component Structure   General Data in Customer Master  
This documentation is copyright by IBM.

Length: 3248 Date: 20240425 Time: 141258     sap01-206 ( 3 ms )