Ansicht
Dokumentation
CPI116F - Hot spare disk unit not in valid location. ( OS/400 )
BAL_S_LOG - Application Log: Log header data Fill RESBD Structure from EBP Component StructureThis documentation is copyright by IBM.
Message : CPI116F
Hot spare disk unit not in valid location.
Message Long Text :
Cause . . . . . : The hot spare disk unit that is protecting the load source disk unit is not in a valid location to allow the system to IPL if the load source disk unit fails. The following information identifies the hot spare disk unit:
Disk serial number: &27
Disk type: &3
Disk model: &4
Device resource name: &26
Recovery . . . : Do the following:
1. Stop hot spare on the indicated disk unit.
2. Start hot spare on a different disk unit under the same Input/Output Adapter. Only disk units in a valid location are selectable for the Start Hot Spare operation. A configuration change may be necessary to create a non-configured disk unit that can be a hot spare to protect the loadsource disk unit.
Message File : QCPFMSG
Library Message File : QSYS2924
BAL_S_LOG - Application Log: Log header data CL_GUI_FRONTEND_SERVICES - Frontend Services
This documentation is copyright by IBM.
Length: 3236 Date: 20240329 Time: 133943 sap01-206 ( 3 ms )