Ansicht
Dokumentation

CPI1303 - Insufficient storage in machine pool to start job &3/&2/&1. ( OS/400 )

CPI1303 - Insufficient storage in machine pool to start job &3/&2/&1. ( OS/400 )

rdisp/max_wprun_time - Maximum work process run time   TXBHW - Original Tax Base Amount in Local Currency  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI1303
Insufficient storage in machine pool to start job &3/&2/&1.

Message Long Text :

Cause . . . . . : Because there was insufficient storage in the machine pool, job &3/&2/&1 was not started. Each job that is started reserves a small amount of storage in the machine pool. Not enough storage could be reserved for the job.
Recovery . . . : Increase the machine pool storage size (CHGSYSVAL command with the QMCHPOOL system value).
-- If storage in the machine pool does not increase, reduce the storage required by any active subsystem pools (CHGSBSD command).
-- The WRKSYSSTS command can be used to display the storage pool usage on the system.
-- Refer to the Work management topic collection in the Systems management category in the IBM i Information Center, http://www.ibm.com/systems/i/infocenter/, for information on defining storage pool sizes.
-- After storage has been added to the machine pool, do the following to start the job again:
-- Use the DSPJOB command to find the type of job; if the job is a subsystem job, submit the STRSBS command;
-- If the job is a reader or writer, end the reader or writer (ENDRDR or ENDWTR command) and start the reader or writer;
-- If the job is an autostart job, end the job (ENDJOB command), end the subsystem that the job is associated with (ENDSBS command) and start the subsystem (STRSBS command);
-- If the job is a prestart job, wait until message CPC0905 appears on the QSYSOPR message queue, indicating that the prestart job entry is no longer active. To start new jobs, enter the Start Prestart Jobs (STRPJ) command.
-- If the job is an interactive or batch job, end the job (ENDJOB command) and submit the request to start the job again.

Message File : QCPFMSG
Library Message File : QSYS2924


rdisp/max_wprun_time - Maximum work process run time   ROGBILLS - Synchronize billing plans  
This documentation is copyright by IBM.

Length: 3259 Date: 20240416 Time: 210201     sap01-206 ( 3 ms )