CPI2617 - Parameter ignored for nonswitched network interface. ( OS/400 )

CPI2617 - Parameter ignored for nonswitched network interface. ( OS/400 )

Addresses (Business Address Services)   General Material Data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI2617
Parameter ignored for nonswitched network interface.

Message Long Text :

Cause . . . . . : One or more of the following parameters was specified. These parameters only apply for a network interface description with at least one channel entry (CHLENTRY parameter) defined as switched (*SWT) or for an X.31 notification class (X31NFYCLS parameter) other than *NONE. Parameters that do not apply are ignored.
-- Local number (LCLNBR)
-- Local number type (LCLNBRTYPE)
-- Local numbering plan (LCLNBRPLAN)
-- Local number presentation (LCLNBRPSN)
-- Characters to remove (RMVCHR)
-- Local subaddress (LCLSUBADR)
-- Local subaddress type (LCLSUBTYPE)
-- Terminal endpoint identifier (TEID)
-- Setup differences (SETUPDIF)
-- Procedural differences (PRCDIF)
-- CRC errors received (CRCRCV)
-- Receive overrun (OVERRUN)
-- Transmit underrun (UNDERRUN)
-- Frame aborts (ABORTS)
-- Retransmitted frames (RETRANSMIT)
-- Frame sequence errors (FRMSEQERR)
Recovery . . . : None required.
Technical description . . . . . . . . : Many of the network interface description parameters only apply if the D channel is used to signal to the Integrated Services Digital Network (ISDN). If all of the B channels of an ISDN network interface are nonswitched (permanent) connections through the network or if the X.31 notification class is *NONE, the D channel is not used and the parameters listed above do not apply.

Message File : QCPFMSG
Library Message File : QSYS2924


rdisp/max_wprun_time - Maximum work process run time   General Data in Customer Master  
This documentation is copyright by IBM.

Length: 3268 Date: 20240425 Time: 032022     sap01-206 ( 5 ms )