Ansicht
Dokumentation

CPI400B - Communication link not started on line &2. ( OS/400 )

CPI400B - Communication link not started on line &2. ( OS/400 )

Addresses (Business Address Services)   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI400B
Communication link not started on line &2.

Message Long Text :

Cause . . . . . : An attempt to start a communication link for line &2 for writer &1 was not allowed. The reason code is &5. The reason codes and their meanings are:
01 - Line name is not valid or protocol not supported.
Recovery: The line name specified must be for a line type of ETHERNET or TRN. Remove the line name &2 from the switched line list parameter in device description &4. X.25 lines can not be used for writers.
02 - The line description, network controller description or network device description is not in a valid state.
03 - Not authorized to the line description or the network controller description.
04 - Can not allocate the network device description.
05 - Can not create the network controller description or network device description.
06 - Could not vary on the network interface, line description, network controller description, or network device description.
07 - Line description &2 not found.
Recovery: Correct the name of the line description in the switched line list of the device description &4 and try the request again.
08 - Line description &2 is damaged.
Recovery: Delete and then create line description &2. Try the request again.
09 - Internal system error occurred when attempting to establish a link for line description &2. The return code is &7 and the reason code is &8.
Recovery: If there is another switched line that can be used to communicate to the device, place that line name in the switched line list of the device description for the printer. Attempt to start the writer again. If the problem continues, report the problem using the ANZPRB command.
10 - An error occurred while attempting to establish a link for line description &2. The return code is &7 and the reason code is &8.
Recovery: Look at previous messages in the job log to determine the problem. The line name may be removed from the switched line list in the device description.
11 - The line supports TCP/IP only.
Recovery: Remove the line name &2 from the switched line list parameter in device description &4. TCP/IP only lines cannot be used for this writer.
Recovery . . . : If a recovery is specified for the reason code, follow those recovery instructions. Otherwise see the messages previously listed in the job log for information on correcting the condition.

Message File : QCPFMSG
Library Message File : QSYS2924


Vendor Master (General Section)   CL_GUI_FRONTEND_SERVICES - Frontend Services  
This documentation is copyright by IBM.

Length: 3258 Date: 20240329 Time: 163546     sap01-206 ( 3 ms )