CPI58E9 - Associated device not configured for device &25. ( OS/400 )
BAL Application Log Documentation ABAP Short ReferenceThis documentation is copyright by IBM.
Message : CPI58E9
Associated device not configured for device &25.
Message Long Text :
Cause . . . . . : Data cannot be sent until an associated Systems Network Architecture (SNA) pass-through device is configured for device &25.
Recovery . . . : In order to recover, use the Work with Device Description (WRKDEVD) command to change device &25. An associated SNA pass-through device (SNPTNAME) must be configured on device &25.
If the problem persists, report the problem (ANZPRB command).