Ansicht
Dokumentation
CPI594B - A networking device incompatible with device &25. ( OS/400 )
General Material Data ROGBILLS - Synchronize billing plansThis documentation is copyright by IBM.
Message : CPI594B
A networking device incompatible with device &25.
Message Long Text :
Cause . . . . . : The probable cause is:
-- An advanced program-to-program communications (APPC) device that is defined as a networking device with the same remote and local location names and remote network identifier as device &25, is already varied on. The maximum number of conversations allowed for device &25 is not compatible with the maximum number of conversations allowed for the device that is already varied on.
Recovery . . . : Do one of the following:
-- Use the Vary Configuration (VRYCFG) command to vary device &25 off. Let the advanced peer-to-peer networking (APPN) support vary device &25 on when the device is to be used.
Technical description . . . . . . . . : The error log identifier is &22. The error code is &40.
Message File : QCPFMSG
Library Message File : QSYS2924
Vendor Master (General Section) ABAP Short Reference
This documentation is copyright by IBM.
Length: 3237 Date: 20240419 Time: 044952 sap01-206 ( 2 ms )