Message : CPI594B
A networking device incompatible with device &25.

Message Long Text :

Cause . . . . . : The probable cause is:
-- An advanced program-to-program communications (APPC) device that is defined as a networking device with the same remote and local location names and remote network identifier as device &25, is already varied on. The maximum number of conversations allowed for device &25 is not compatible with the maximum number of conversations allowed for the device that is already varied on.
Recovery . . . : Do one of the following:
-- Use the Vary Configuration (VRYCFG) command to vary device &25 off. Let the advanced peer-to-peer networking (APPN) support vary device &25 on when the device is to be used.
Technical description . . . . . . . . : The error log identifier is &22. The error code is &40.

Message File : QCPFMSG