CPI5969 - Session maximum not established for mode &2 device &1. ( OS/400 )
General Data in Customer Master General Material DataThis documentation is copyright by IBM.
Message : CPI5969
Session maximum not established for mode &2 device &1.
Message Long Text :
Cause . . . . . : The remote system logical unit sent data that is not valid. See message &3 on the QHST message log (DSPLOG command) for a description of the data that is not valid. A request to change the session maximum, initiated by the system for mode &2 device &1, may have failed.
Recovery . . . : If the negotiated session maximum is not at the correct value (DSPMODSTS command), change the session maximum (CHGSSNMAX command).
If the problem continues, report the problem (ANZPRB command).
Technical description . . . . . . . . : Remote system logical unit sent a reply that is not valid to the transmitted session maximum negotiation request.