Controller not known to local system. Call came in on line &1.

Message Long Text :

Cause . . . . . : A remote system with remote network identifier (RMTNETID) &5, remote control point name (RMTCPNAME) &6, exchange identifier (EXCHID) &4, system service control point identifier (SSCPID) &3, and adjacent link station name (ADJLNKSTN) &7 tried to establish a synchronous data link control (SDLC) switched connection with this system. No varied on controller description had parameters matching the call.
Recovery . . . : Verify that the proper controllers are varied on and configured correctly.
For APPC controllers, the following must be true for call acceptance:
- an APPC controller is vary on pending
- RMTNETID RMTCPNAME, or EXCHID, or all were received
- if RMTNETID or RMTCPNAME was configured in the controller description intended for the call, it must match the value received from the adjacent system. If neither value was configured or received, check other parameters.
- if EXCHID was configured in the controller description intended for the call, it must match the value received from the adjacent system. If this value was not configured or received, check other parameters.
- at least one of the above parameters must match an APPC controller description in vary on pending state to find the controller description. If certain values are not configured or received, a configuration change may be needed.
- For HOST controllers, the following must be true for call acceptance:
- a HOST controller is in vary on pending state
- RMTNETID RMTCPNAME, SSCPID, ADJLNKSTN, or all were received
- if RMTNETID or RMTCPNAME was configured in the controller description intended for the call, it must match the values received from the adjacent system. If these values were not configured or received, check other parameters.
- if SSCPID was configured in the controller description intended for the call, it must match the value received from the adjacent system. If this value was not configured or received, check other parameters.
- if ADJLNKSTN was configured in the controller description intended for the call, it must match the value received from the adjacent system. If this value was not configured or received, check other parameters.
- at least one of the above parameters must match for a HOST controller description in vary on pending state to find the controller description. If certain values are not configured or received, a configuration change may be needed.

Message File : QCPFMSG
Library Message File : QSYS2924