Ansicht
Dokumentation

CPI59E3 - Line &23 failed, hardware error occurred. ( OS/400 )

CPI59E3 - Line &23 failed, hardware error occurred. ( OS/400 )

BAL_S_LOG - Application Log: Log header data   BAL_S_LOG - Application Log: Log header data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI59E3
Line &23 failed, hardware error occurred.

Message Long Text :

Cause . . . . . : A direct memory access (DMA) hardware error occurred for a frame being received while line &23 was using network interface &30. The ISDN cause code associated with the call is &43 (&45 &46).
Recovery . . . : Do one or more of the following:
-- Use the Vary Configuration (VRYCFG) command to vary network interface &30 off, then on.
-- Use the VRYCFG command to vary network interface &30 off. Then use the VRYCFG command with reset (RESET parameter) specified as yes (*YES) if allowed to reset the input/output processor (IOP) and to vary network interface &30 on.
If the system sends a diagnostic message because other network interfaces on that IOP are varied on, vary them off. Then vary network interface &30 on with the RESET parameter specified as *YES if allowed.
If the problem continues, press F14 to run problem analysis.
Technical description . . . . . . . . : The error log identifier is &22. The reason code is &40: A DMA hardware error occurred while receiving a frame.
The ISDN cause information element is: &44.