Ansicht
Dokumentation

CPI5DA0 - CP-SVR pipe to DLUS &3.&4 on controller &7 not established. ( OS/400 )

CPI5DA0 - CP-SVR pipe to DLUS &3.&4 on controller &7 not established. ( OS/400 )

rdisp/max_wprun_time - Maximum work process run time   Fill RESBD Structure from EBP Component Structure  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI5DA0
CP-SVR pipe to DLUS &3.&4 on controller &7 not established.

Message Long Text :

Cause . . . . . :
The remote system sent Systems Network Architecture (SNA) negative response data to the local system. The local system attempted to initiate a CP-SVR pipe with the remote system for controller &7. The remote system configured in the DLUR controller as the Dependent Logical Unit Server (DLUS) does not appear to be a DLUS.
Recovery . . . :
Vary off controller &7 (VRYCFG command).
Change the controller description (CHGCTLD command) to specify the network identifier and control point name of a remote system which provides DLUS support. Change the primary DLUS (PRIDLUS parameter) if DLUS &3.&4 is specified as the primary DLUS. Change the backup DLUS (BKUDLUS parameter) if DLUS &3.&4 is specified as the backup DLUS.
Vary on controller &7 (VRYCFG command).
Technical description . . . . . . . . :
The DLUS sent SNA sense data &1.
The SNA sense data and the problem detected follows:
088E 0009 - DLUR detected compatibilities mismatch.
For information about other SNA sense data, see the SNA Formats, GA27-3136.

Message File : QCPFMSG