Ansicht
Dokumentation

CPI5DB2 - CP-SVR pipe to DLUS &3.&4 on controller &7 not established. ( OS/400 )

CPI5DB2 - CP-SVR pipe to DLUS &3.&4 on controller &7 not established. ( OS/400 )

General Material Data   BAL Application Log Documentation  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI5DB2
CP-SVR pipe to DLUS &3.&4 on controller &7 not established.

Message Long Text :

Cause . . . . . :
The Dependent Logical Unit Server (DLUS) &3.&4 sent Systems Network Architecture (SNA) negative response data. This is caused by a configuration error which must be corrected before a CP-SVR pipe can be established to DLUS &3.&4.
Recovery . . . :
If DLUS &3.&4 is the primary DLUS (PRIDLUS parameter) for controller &7 and if a backup DLUS is specified (BKUDLUS parameter), the local system attempts to contact the backup DLUS.
The configuration error must be corrected before a CP-SVR pipe can be established to DLUS &3.&4.
Verify these parameters for the controller on both the local system and the DLUS:
On the local system, display the controller description (DSPCTLD command) to verify the following:
-- Local Exchange Identifier (LCLEXCHID)
To verify this information at the DLUS, contact the system administrator. Request the system administrator to display the physical unit (PU) definition to verify the block identifier and number identifier.
The local exchange identifier parameter cannot be changed in controller description &7.
If this parameter is not correct in controller description &7, do the following:
-- Vary off the controller description (VFYCFG command)
-- Delete the existing controller description (DLTCTLD command)
-- Create a controller description (CRTCTLHOST command) with the correct value.
-- Vary on the controller description (VFYCFG command)
If the value specified on the remote system is incorrect, request that the system administrator change the definition to specify the correct value.
Technical description . . . . . . . . :
The DLUS sent SNA sense data &1.
The SNA sense data and the problem detected follows:
0809 0000 - The XID was rejected by the DLUS.
The local system sent local exchange identifier &8.
088E 0008 - The DLUS detected a capabilities mismatch.
For information about other SNA sense data, see the SNA Formats, GA27-3136.

Message File : QCPFMSG
Library Message File : QSYS2924


CL_GUI_FRONTEND_SERVICES - Frontend Services   General Data in Customer Master  
This documentation is copyright by IBM.

Length: 3283 Date: 20240423 Time: 174031     sap01-206 ( 2 ms )