CPI7E42 - Error with device &25 on workstation controller &24. ( OS/400 )

CPI7E42 - Error with device &25 on workstation controller &24. ( OS/400 )

SUBST_MERGE_LIST - merge external lists to one complete list with #if... logic for R3up   General Data in Customer Master  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI7E42
Error with device &25 on workstation controller &24.

Message Long Text :

Cause . . . . . : Device &25 on workstation controller &24 was varied on and no printer definition table was specified. A printer definition table was previously down loaded to device &25 and cannot be removed or replaced.
Recovery . . . : Power off device &25 and then power it back on. Put device &25 in off-line setup mode when it is powering on. While device &25 is in off-line setup mode, select either a user-defined printer session with ASCII printer ID 00, or a standard printer session. Exit from off-line setup mode. If the problem persists, report the problem to your hardware service provider.

Message File : QCPFMSG
Library Message File : QSYS2924