Ansicht
Dokumentation

CPI7F7E - Error on network interface &30. ( OS/400 )

CPI7F7E - Error on network interface &30. ( OS/400 )

PERFORM Short Reference   General Material Data  
This documentation is copyright by IBM.
SAP E-Book


Message : CPI7F7E
Error on network interface &30.

Message Long Text :

Cause . . . . . : The following may have caused the problem:
-- The ISDN network or the remote data communications equipment may not be working correctly.
-- The I/O card Licensed Internal Code may not be working correctly.
Recovery . . . : If you suspect the ISDN network or the remote data communications equipment is causing this problem, consult your local ISDN network provider. If the problem persists, press F14 to report the problem.
Technical description . . . . . . . . : A frame with a wrong NR count was received. The local system has responded with a set-asynchronous-mode-extended (SABME) frame in an attempt to reestablish communications. If this attempt is successful, you may experience no further problems and you may ignore the message.

- Problem Log ID ........: &35
- Error Log ID ..........: &22
- Processor Resource ....: &26
- Adapter Resource ......: &27
- Port Resource .........: &28

Message File : QCPFMSG
Library Message File : QSYS2924


Addresses (Business Address Services)   rdisp/max_wprun_time - Maximum work process run time  
This documentation is copyright by IBM.

Length: 3231 Date: 20240419 Time: 030939     sap01-206 ( 4 ms )